Feature Products

EBTRON ELECTRONIC AFMS

Ebtron Plug and Play electronic AFMS provide accuracy and repeatability!
Model GTA116 Transmitter/Sensor Probes
Precise Measurement for Ducts, Plenums or Fan Inlets, and Across Dampers, Louvers, or Between Spaces
  • Accurate and repeatable measurement
  • Factory calibrated to NIST traceable airflow and temperature standards
  • True average, independent multi-point sensing
  • Advanced Thermal Dispersion (TD) airflow measurement technology
  • Microprocessor based digital circuitry
  • Exclusive "plug and play" smart sensor design
GTA116-P
Ducts and Plenums
Precision Airflow/Temperature Measurement

 

GTA116-F
Fan Inlet Airflow/Temperature Measurement

 

GTA116-B
"Bleed" Airflow/Pressure Measurement

PACKAGED PENTHOUSE WATER COOLED CHILLER FOR OUTDOOR LOCATION

OUTDOOR WATER COOLED CHILLERS

The retrofit of the existing building did not provide sufficient mechanical room space for the installation of conventional indoor water cooled chillers.

Technical Systems solved the problem by designing and fabricating self-contained chiller penthouses for outdoor location.  Each modular penthouse encloses the chiller, compressors, condenser, evaporator, and control panel in a walk-in enclosure.  The enclosure provides a safe and dry environment for maintainance personnel as well as housing the chiller.  Each 150 ton chiller features dual independently circuited rotary screw compressors.

End view of chiller with factory installed and wired disconnect

Enclosure full height access door to control panel compartment and cooling tower water piping connections

Cooling tower located adjacent to chiller penthouses

ARMSTRONG HUMIDIFIERS

ELECTRIC HUMIDICLEAN
  • Electric Resistance Heating Elements
  • Ionic Bed Technology


ELECTRIC HUMIDIFIER
  • Self Contained Electric
  • Electrode Type
EHU
STEAM INJECTION TYPE
 
 
 

GFH
  • Gas Fired Humidifier
  • Ionic Bed Technology
GHF

ADVANCE CONTROLS, INC.

Inverter Bypass Safety Switch Transfer Switch


 

For Variable Frequency Drives


 

Load Break Disconnect Switches
 

Motor and Combination Starters


SAFTRONICS VARIABLE SPEED DRIVES AND SOLID STATE STARTERS

TOWERPAK
Cooling Tower Controller
  • Soft Switching 4th Generation IGBT's
  • NEMA 3R Enclosure with Space Heater
  • 3 Contactor Bypass
  • Cooling Tower Options
    • Fluid Cooler Spray Pump Starter
    • Damper Control
    • Basin Heater Contactor
    • Basin Temperature Controller
    • De-Icing Control
  • Enhanced LED / LCD Keypad with Memory
    • VFD Diagnostic Display
    • VFD Maintenance Display

 

HR1018
Harmonic Reduction Technology
  • Soft Switching 4th Generation IGBT's
  • NEMA 12 PPBF Enclosure
  • Low Harmonic Distortion
    • 18 Pulse Configuration
  • Anti-Windmilling / Smart Speed Search
  • 3 Contractor Bypass
  • Precise Control fo HVAC Applications
    • Pumps, Fans, and Cooling Towers
  • Enhanced LED / LCD Keypad with Memory
    • VFD Diagnostic Display
    • VFD Maintenance Display
BYPASS PACKAGES
FPC5010M - Mini Bypass Package
FPC5010 - Standard Bypass Package
FPC5010S - Smart Bypass Package
  • Soft Switching 4th Generation IGBT's
  • NEMA 1, NEMA 12, or NEMA 3R Enclosures
  • Low Harmonic Distortion
    • 3% Equivalent Reactor
  • Anti-Windmilling / Smart Speed Search
  • 3 Contactor Bypass
  • Enhanced Control for HVAC Applications
    • VFD Diagnostic Display
    • VFD Maintenance Display
AS6
Automation Starter
  • Advanced Solid-State Reduced Voltage Motor Starter
  • Torque Ramp for Linear Acceleration
  • Simple Setup
  • Enhanced Setup for the more Demanding Applications
  • Forward / Reverse Jogging 
  • Complete Monitoring Package Eliminates Need for Add On Devices
  • Extensive Protection Features For Motor and Starter
  • Rugged Compact Design
  • Dynamic Motor Mapping Fine Tunes Every Start
  • Serial Communications
  • Available From 7.5 HP to 1000 HP (460 V)
Drive with Disconnect Packages
FPC510M - Mini Drive with Disconnect
FPC 510 - Standard Drive with Disconnect
  • Convenient, Low Cost Installation
  • Soft Switching 4th Generation IGBT's
  • NEMA 1, NEMA 12, or NEMA 3R Enclosures
  • Advanced Energy Savings
  • Low Harmonic Distortion
    • 3% Equivalent Reactor
  • Anti-Windmilling / Smart Speed Search
  • Precise Control for HVAC Applications
    • Pumps, Fans, and Cooling Towers
  • Enhanced LED / LCD Keypad with Memory
    • VFD Diagnostic Display
    • VFD Maintenance Display

 
 